Image is an illustration, may not reflect the exact product sold.


Other products by Restek

Restek - 16107 - Rxi-1301Sil MS Cap. Column 60m, 0.53mm, 3.0um

  • MFR SKU: 16107
  • ITEM #: 10307521
  • 0 Reviews / 0 Questions
Lists At: $1,234.00 You Save: $45.86
3.72 % OFF
$1,188.14
Stock Status: Call For Stock (shipping delay possible)
Average lead time for this brand: 1-2 weeks. Specific products may vary.

ITEM #: 10307521
midpolarity Crossbond phase
Cyano-based 1301 columns are general use GC columns that are well suited for the analysis of solvents across a range of volatilities. The cyano stationary phase provides more retention of polar compounds than a 5-type column; however, cyano-based stationary phases are prone to high bleed and poor robustness, limiting their utility. The new R x i-1301Sil MS column from Restek is a silarylene-based cyano stationary phase that not only provides the column selectivity...
ITEM #: 10307521
midpolarity Crossbond phase
Cyano-based 1301 columns are general use GC columns that are well suited for the analysis of solvents across a range of volatilities. The cyano stationary phase provides more retention of polar compounds than a 5-type column; however, cyano-based stationary phases are prone to high bleed and poor robustness, limiting their utility. The new R x i-1301Sil MS column from Restek is a silarylene-based cyano stationary phase that not only provides the column selectivity needed for analyzing less volatile compounds, but also significantly lowers column bleed and improves robustness.
The low ma x imum operating temperature that is characteristic of non-silarylene cyano phases is a well known drawback to using traditional 1301 columns for volatiles analysis. Due to their high bleed and low ma x imum temperatures, many 1301 columns do not perform well for MS analyses. In contrast, the robust R x i-1301Sil MS column works e x tremely well for MS applications because it offers the highest ma x imum temperature and lowest bleed in the industry, leading to much more reliable and accurate MS results. E x ceptionally high thermal stability produces robust column performance and allows for more aggressive thermal ramping to eliminate carryover of high molecular weight compounds between analyses (i.e., increased uptime).
In addition to providing both true 1301 selectivity and the lowest bleed/highest temperature limits in the industry, the R x i-1301Sil MS column is designed to provide a high degree of inertness. Each R x i-1301Sil MS column is tested with a QC mi x that includes both acidic and basic probes to ensure inertness across multiple compound classes. Greater column inertness improves peak shape and response, ensuring more accurate quantitative results.
The new R x i-1301Sil MS column is ideal for the analysis of multiple compound classes across a range of polarities and volatilities. With its cyano-based selectivity and high thermal stability, it is the best 1301-type column for robust MS analyses.
  • Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
  • Stabilized cyano phase selectivity improves the performance of e x isting methods. Ideal for solvents, glycols, and other polar compounds.
  • Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
  • Ma x imum temperature: 320°C

Rxi-1301Sil MS Cap. Column 60m, 0.53mm, 3.0um
This listing is for Each
Read More >>

Restek - 16107 - Rxi-1301Sil MS Cap. Column 60m, 0.53mm, 3.0um

  • Item #: 10307521
  • MFR SKU: 16107

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items