ITEM #: 11441374
Lowell 3
5' module: SINGLE (2) 15A (NEMA 5-15R)
The POWERSTAC™ modular power system let’s you custom design a power strip to accommodate specific needs of almost any application . Blank modules allow room for future expansion . Save time in the field by ordering a ganging or enclosed rack with a pre-mounted POWERSTAC . †
Full Component Library: J-boxes for internal or external rackmount, chassis lengths up to 75', single or multi-circuit power modules (15A, 20A,...
ITEM #: 11441374
Lowell 3
5' module: SINGLE (2) 15A (NEMA 5-15R)
The POWERSTAC™ modular power system let’s you custom design a power strip to accommodate specific needs of almost any application . Blank modules allow room for future expansion . Save time in the field by ordering a ganging or enclosed rack with a pre-mounted POWERSTAC . †
Full Component Library: J-boxes for internal or external rackmount, chassis lengths up to 75', single or multi-circuit power modules (15A, 20A, 30A, remote control and surge suppression options, new IEC outlets) .
Field-Changeable Modules: the patented rotating outlet design (US patent D535178S) allows individual power modules to be repositioned in the field without removing the entire power strip from the rack .
New Flexible-conduit Option: 6' non-metallic flexible conduit .
New “SIG” Option: the default grounding scheme for configurations with isolated ground circuits is a common IG conductor . You can also order an independent conductor for each circuit by adding the “SIG” suffix to the end of the custom model number (additional charges apply) . Note: there are limitations to the number of circuits that will fit into a single unit . When the “SIG” option is selected with the 6' flexible-conduit configuration, the default conduit size is 1 . 25' .
Easy to Design: three basic steps: select the components (chassis/J-box or chassis/flexible-conduit combination, individual power modules), create a custom part number, and indicate where the strip is to be mounted in the rack (additional worksheets are available, please contact us at (888) 736-6888) .
1) . Power Layout: select chassis length and J-box (or 6' non-metallic flexible conduit) according to rack height and position of outlets . The J-box can be positioned inside or outside the rack . † Locate chassis/J-box or chassis/flexible-conduit I . D . (single character for 75', two characters for 60', three characters for 30') and record number in top box . Then select individual power modules (see pg . 56 for descriptions) and record module I . D . numbers in order desired, placing one character in each box as on shown (please see Spec Sheet) .
2) . Custom Part No . : transfer module numbers (in order) to create the custom part number . Fill all boxes, adding blank modules to fill gaps . If the SIG option is desired, add “SIG” as a suffix outside the boxes .
3) . Rackmount Position: indicate rackmount position . If none is indicated, default postion will be used for positioning outlets .